Sevofluranum [INN-Latin]

PURITAN-BENNETT CORPORATION    -- SEVOFLURANE, SEVOFRANE; ARGON                
=======================================================
MSDS Safety Information 
=======================================================
FSC: 6830
MSDS Date: 04/01/1991
MSDS Num: CJJNX
LIIN: 00N091250
Product ID: SEVOFLURANE, SEVOFRANE; ARGON
MFN: 01
Responsible Party
Cage: 16827
Name: PURITAN-BENNETT CORPORATION
Address: 10800 PFLUMM ROAD
City: LENEXA KS 66215
Info Phone Number: 913-469-5400
Emergency Phone Number: 913-469-5400
Proprietary Ind: Y
Review Ind: Y
Published: Y
=======================================================
Contractor Summary 
=======================================================
Cage: 16827
Name: PURITAN-BENNETT CORPORATION
Address: 10800 PFLUMM ROAD
City: SHAWNEE KS 66215
Phone: 913-649-5400
=======================================================
Item Description Information 
=======================================================
=======================================================
Ingredients 
=======================================================
Name: *** PROPRIETARY  ***
-----------------------------
=======================================================
Health Hazards Data 
=======================================================
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: HEADACHE, DIZZINESS, UNCONSCIOUSNESS, DEATH.
Explanation Of Carcinogenicity: NOT LISTED IN NTP OR IARC; NOT REGULATED AS A
  CARCINOGEN BY OSHA.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
First Aid: SEEK MEDICAL ATTENTION. EYES: IMMEDIATELY FLUSH WITH LARGE AMOUNTS
  OF TEPID POTABLE WATER FOR AT LEAST 15 MINUTES. SKIN: REMOVE CONTAMINATED
  CLOTHING. IF REDNESS OR IRRITATION RESULTS, SEEK MEDICAL AT TENTION.
  INHALATION: REMOVE PERSON FROM EXPOSURE. INGESTION: CALL MD IMMEDIATELY (FP
  N).
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: PROVIDE ADEQUATE VENTILATION TO MAINTAIN OXYGEN
  CONCENTRATION ABOVE 19.5% BY VOLUME. EMERGENCY PERSONNEL WILL REQUIRE NIOSH
  APPROVED SCBA IF OXYGEN CONCENTRATION IS BELOW 19.5% BY VOLUME.
Waste Disposal Methods: DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
  REGULATIONS (FP N). VENT TO ATMOSPHERE IN AN OPEN AREA.
Handling And Storage Precautions: CYLINDERS SHOULD NOT BE DROPPED. KEEP
  PROPERLY SECURED OR PROTECTED TO PREVENT CYLINDERS FROM BEING KNOCKED OVER.
  MATERIAL CAN BE STORED OUTSIDE. TEMPERATURE SHOULD BE KEPT BELOW 125F.
Other Precautions: CYLINDERS SHOULD BE STORED UPRIGHT WITH VALVE CAP IN PLACE.
  CYLINDERS MUST NOT BE RECHARGED UNLESS BY OR WITH CONSENT OF PURITAN-BENNETT
  CORPORATION.
=======================================================
Fire and Explosion Hazard Information 
=======================================================
Flash Point Text: NOT AVAILABLE
Lower Limits: NOT AVAIL
Upper Limits: NOT AVAIL
Extinguishing Media: MEDIA SUITABLE FOR SURROUNDING FIRE (FP N). MIXTURE IS
  NON-FLAMMABLE; WILL NOT SUPPORT COMBUSTION.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT
  (FP N). KEEP CYLINDERS COOL WITH WATER SPRAY.
Unusual Fire/Explosion Hazard: EXCESSIVE PRESSURE CAN BUILD UP DUE TO HEAT.
  CYLINDERS MAY EXPLODE IF PRESSURE RELIEF DEVICES FAIL TO RELIEVE PRESSURE.
=======================================================
Control Measures 
=======================================================
Respiratory Protection: EMERGENCY PERSONNEL WILL REQUIRE A NIOSH APPROVED
  SELF-CONTAINED BREATHING APPARATUS IS OXYGEN CONCENTRATION IS BELOW 19.5% BY
  VOLUME.
Ventilation: LOCAL EXHAUST RECOMMENDED. PROVIDE ADEQUATE VENTILATION TO
  MAINTAIN OXYGEN CONCENTRATION ABOVE 19.5% BY VOLUME.
Protective Gloves: COTTON, LEATHER OR NEOPRENE GLOVES.
Eye Protection: ANSI APPROVED CHEMICAL WORKERS GOGGLES (FP N).
Other Protective Equipment: ANSI APPROVED EYE WASH & DELUGE SHOWER (FP N).
  SAFETY SHOES WHEN HANDLING CYLINDERS.
Supplemental Safety and Health: PHYSICAL DATA: VAP DENS: 0.967 (APPROX)
  (AIR=1).
=======================================================
Physical/Chemical Properties 
=======================================================
B.P. Text: NOT AVAILABLE
Vapor Pres: NOT AVAILABLE
Vapor Density: SUPP DATA
Evaporation Rate & Reference: GAS
Solubility in Water: SLIGHT
Appearance and Odor: COLORLESS & ODORLESS GAS.
Percent Volatiles by Volume: 100
=======================================================
Reactivity Data 
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: EXCESSIVE HEAT.
Materials To Avoid: NONE.
Hazardous Decomposition Products: NONE KNOWN.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: WILL NOT OCCUR.
=======================================================
Other Information 
=======================================================
Other Information: ADDNL INFO: PLEASE REFER TO CGA BULLETIN SB-2 "OXYGEN
  DEFICIENT ATMOSPHERES", AND CGA PAMPHLETS P-1 "SAFE HANDLING OF COMPRESSED
  GASES IN CONTAINERS", P-9 "THE INERT GASES, ARGON, NITROGEN AND HELIUM" , AND
  P-14 "ACCIDENT PREVENTION IN OXYGEN-RICH AND OXYGEN-DEFICIENT ATMOSPHERES".
=======================================================
HAZCOM Label 
=======================================================
Product ID: SEVOFLURANE, SEVOFRANE; ARGON
Cage: 16827
Company Name: PURITAN-BENNETT CORPORATION
Street: 10800 PFLUMM ROAD
City: SHAWNEE KS
Zipcode: 66215
Health Emergency Phone: 913-469-5400
Label Required IND: Y
Date Of Label Review: 04/28/1999
Status Code: A
Origination Code: F
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: None
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: ACUTE:	HEADACHE, DIZZINESS, UNCONSCIOUSNESS, DEATH. 
  CHRONIC: NONE SPECIFIED BY MANUFACTURER (FP N).
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
  information is formulated for use by elements of the Department of Defense.
  The United States of America in no manner whatsoever expressly or implied
  warrants, states, or intends said information to have any application, use or
  viability by or to any person or persons outside the Department of Defense
  nor any person or persons contracting with any instrumentality of the United
  States of America and disclaims all liability for such use. Any person
  utilizing this instruction who is not a military or civilian employee of the
  United States of America should seek competent professional advice to verify
  and assume responsibility for the suitability of this information to their
  particular situation regardless of similarity to a corresponding Department
  of Defense or other government situation.